Selecting or tuning an induction sealing machine requires translating container throughput into physical conveyor velocity and exposure duration under the coil. Identical containers-per-minute rates can yield different feet-per-minute line speeds and dwell times depending on closure spacing, which affects induction cap sealer power-supply sizing across your manufacturing automation line.

Line speed is one of the factors that determines the appropriate size induction sealing power supply for an application. When line speed is measured in containers per minute, it is a relative term. Dwell time is the amount of time the container spends traveling underneath the cap sealer. The three sealing absolutes in induction sealing are Pressure, Heat, and Time.

Why Containers Per Minute Does Not Equal Dwell Time

When evaluating an induction cap sealer for a packaging line, container pitch determines how fast bottles actually move beneath the sealing head. Compare how container spacing changes linear belt speed in the following worked comparison.

To calculate conveyor speed in FPM, divide the number of containers per minute by the number of containers per foot to get line speed in feet per minute.

Line scenarioVerified speed and dwell calculation
First pitch Company A running 200 containers per minute (CPM) with 12 inches of pitch between closure centers has 1 container per foot (CPF).
First speed In the Company A example, line speed is 200 CPM / 1 CPF = 200 FPM.
Second pitch Company B running the same container at 200 CPM with 6 inches of pitch between containers has 2 CPF.
Second speed In the Company B example, line speed is 200 CPM / 2 CPF = 100 FPM.
Dwell ratio Company A's product traveling at 200 FPM spends 1/2 the amount of time under the cap sealer compared to Company B's product traveling at 100 FPM.

When container spacing changes across upstream stars, belts, or accumulation zones, evaluate belt speed alongside production line balancing and packaging bottlenecks.

How Induction Cap Sealing Works: Pressure, Heat, and Time

Before increasing power settings on an induction sealing machine, review how the power supply, sealing head, closure, and liner interact.

Induction sealing creates a hermetic seal by passing a capped bottle under the induction sealer in a non-contact process. Heat from the foil liner, coupled with the pressure of the cap, causes the inner-seal to bond to the lip of the container resulting in a hermetic seal. The FDA recognizes induction sealing as an effective means of tamper evidence. A standard induction sealing system has two main components: the power supply and the sealing head. When energized by the power supply, the sealing head produces an electromagnetic current called an eddy current. Where an inner-seal liner is a two-piece construction, the heated foil melts the wax layer, which is absorbed into the pulp board to release the foil. With metal caps, the sealing equipment heats both the inner-seal foil and the metal cap, and hot metal caps could melt the plastic threads of a container.

Closure Application Torque and Liner Contact

Use these application torque rules to verify cap pressure before containers enter the sealing field:

  • To ensure a good seal, the foil innerseal must be in intimate contact with the lip of the container prior to entering the induction sealer.
  • The industry rule of thumb for proper application torque is one-half of the diameter of the cap, in inch pounds.
  • Under the industry rule of thumb, for a 38mm closure, target application torque should be 18-20 inch pounds.
  • Under the industry rule of thumb, a 63mm cap requires 30-32 inch pounds of application torque.
White plastic bottles with bonded aluminum foil innerseal and upturned screw cap on a stainless steel inspection table
Inspect cap application and innerseal contact before adjusting induction sealer power settings.

Air Gap Geometry and Closure Selection: Flat vs Tunnel Sealing Heads

Closure geometry and liner diameter dictate how electromagnetic energy couples to the foil innerseal during the available dwell window.

Ideally, the foil liner should be 1/8″ to 1/4″ away from the bottom of the sealing head, where maximum field strength is provided. The strength of the electromagnetic field generated by an induction sealer dissipates exponentially with respect to the distance from the sealing head. While the foil in a flat continuous thread (CT) cap is very near the top, the foil in a child resistant closure (CRC) may be as much as 1/4“ from the top of the cap. It takes more energy to seal a smaller liner than a large one because as the liner increases in size, it increases the amount of metal mass available to be heated.

Matching Coil Architecture to Closure Geometry

Compare tunnel and flat coil architectures along with frequency and head skew adjustments:

  • Tunnel sealing heads are generally used when the foil liner diameter is less than 53mm and for closures where there is a larger gap between the liner and the top of the closure.
  • A tunnel sealing head directs the induction field from the top and sides of the container.
  • Flat sealing heads are ideal for sealing most containers with a liner close to the top of the cap and for caps with diameters of more than 53mm.
  • A flat sealing head directs the induction field straight down towards the foil liner.
  • If an induction system does not have the correct coil design, increasing the power of the power supply only wastes energy and does not significantly improve consistent sealing.
  • Depending on the frequency of the sealing system, complete wax melt may not be achieved when using two-piece, wax bonded innerseals.
  • Coil design—not power supply rating alone—determines how much electromagnetic energy couples into the foil liner; Enercon’s technical notes cite deep-tunnel sealing heads for tall sports caps as an example of geometry-specific coil design.
  • On the Accutek Automatic Induction Sealer, the adjustable sealing head mounting includes the ability to skew, which reduces exposure times if necessary, achieving a more uniform heat pattern for larger closures.

Step-by-Step Procedure to Dial In Your Induction Sealing Operating Window

Follow this sequence on the packaging line to establish the upper and lower power boundaries for a given conveyor speed:

  • Step 1 of finding the induction sealing operating window is to verify sealing head air gap and container alignment.
  • Step 2 of finding the operating window is to verify conveyor speed, using a handheld tachometer as a tool for this step.
  • To determine the top power level for the sealing window, once a perfect seal is achieved, increase the power level by 5% until there are signs of the liner burning or wrinkling.
  • After liner burning or wrinkling appears, reduce the power level by 1% until sealing a container without signs of burning or wrinkling to find the top power level.
  • To determine the low power level for the sealing window, from the power level where a perfect seal was first achieved, reduce the power by 5%.
  • When the level is found where the seal is imperfect, increase the sealing power by 1% until achieving a perfect seal to find the low power level.
Stainless steel induction cap sealer head suspended with a narrow air gap above capped white bottles on a conveyor with guide rails and photoelectric sensor
Verify the air gap and container alignment under the sealing head before running line-speed trials.

Line Stoppages, Backup Detection, and Container Inspection Controls

Include sensor verification in your packaging machine maintenance checklist.

Foil caps should never sit idle under an active induction sealing head. On Enercon Super Seal™, an optional Stalled Container Detector detects a stalled container under the sealing head and automatically turns off the sealer. On Enercon Super Seal™, optional Container Backup Detection detects container backups entering and exiting the sealer and automatically turns the sealer off. The Cocked Cap Detector on Super Seal™ Pro detects if a cap is not properly seated on a bottle.

Conveyor Induction Cap Sealers vs Handheld Induction Sealer Specifications

Compare published model specifications across conveyor-mounted systems and benchtop handheld induction sealer units in the table below.

System categoryVerified manufacturer specification
Conveyor unit Super Seal™ dimensions are 11 11/16" x 18 11/32" x 16 1/2" (297 mm x 466 mm x 419 mm).
Conveyor weight Super Seal™ weight is 42 lbs. (19.07 kg).
Conveyor power Super Seal™ input voltage is 240V, 50/60Hz, 1 Phase.
Washdown rating Super Seal™ is IP55 rated for washdown.
Ambient limit Enercon systems are designed to operate in a maximum ambient temperature of 40°C (104°F) @ 80% relative humidity, non-condensing.
Stainless enclosure Super Seal™ Pro has a stainless steel enclosure rated IP55 for wash down.
Universal input Super Seal™ Pro has universal input voltage compatibility from 200V through 240V.
High-speed input Super Seal™ Max input voltage is 200-240V, 14A, 3ph (single phase available).
Operating range Super Seal™ Max ambient temperature range is 5-40°C (41-104°F).
Handheld caps Super Seal™ Jr. handheld induction sealer standard sealing head seals cap diameters up to 83mm, with an available sealing head capable of sealing cap diameters up to 120mm.
Handheld size Super Seal™ Jr. specifications list dimensions as 3" x 8.25" x 10.5" (76mm x 210mm x 267mm); CE specifications list 76mm x 210mm x 318mm (3" x 8.25" x 12.5").
Handheld weight Super Seal™ Jr. weight is 8 lbs. (3.6 kg).
Handheld power Super Seal™ Jr. specifications list input voltage as 120 VAC, 60 Hz; CE specifications list 240 VAC, 50 Hz.
Handheld operation To seal with the handheld Super Seal™ Jr., set the power level and timer to the required seconds, place the sealing head on the cap, and press the trigger.
Solid-state unit The Accutek Automatic Induction Sealer is a four-kilowatt solid-state unit.
Closure capacity The Accutek Automatic Induction Sealer is rated for Cap Size up to 12 cm.
Speed rating The Accutek Automatic Induction Sealer is rated for Speed up to 300 CPM.
Technician in blue nitrile glove holding a handheld induction sealer head flat against a capped bottle on a stainless steel workbench
Use a handheld induction sealer with a manual trigger and timer for benchtop or low-throughput sealing.

Packaging Line Dwell-Time and Sealer Setup Worksheet

Copy these setup fields into your line qualification log before locking in power supply and conveyor settings.

Worksheet fieldWhat to record on the lineVerification question
Container throughputTarget containers per minute from the filler and capperDoes the count reflect steady-state conveyor flow?
Closure center pitchMeasured spacing between adjacent closure centers on the beltHow many containers occupy each linear foot of conveyor?
Linear conveyor velocityCalculated belt speed verified with a handheld tachometerDoes tachometer speed match calculated feet per minute?
Closure and liner typeFlat continuous thread, child resistant, metal cap, or two-piece wax linerHow far sits the foil liner beneath the top of the cap?
Application torqueMeasured cap torque in inch pounds prior to the sealerIs the foil innerseal pressed tightly against the container lip?
Sealing head geometryFlat coil, tunnel coil, deep tunnel coil, or skewed head mountDoes coil orientation match liner diameter and cap recess depth?
Air gap clearanceMeasured clearance between sealing head bottom and foil liner planeAre guide rails centered to maintain uniform clearance?
Operating window boundsUpper power level before scorching and lower power level for full bondWhere does the production setpoint sit between both limits?
Stoppage protectionStalled container detection, backup detection, and cocked cap rejectionDoes the power supply de-energize immediately when the belt stops?

Sources

  • Enercon Industries — Line Speed Calculator
  • Enercon Industries — Tips Every Induction Sealer Operator Should Know
  • Enercon Industries — How Induction Sealing Works
  • Enercon Industries — Induction Cap Sealing Basics: How it Works and Keys for Successful Sealing
  • Enercon Industries — Improve Your Induction Cap Sealing IQ
  • Enercon Industries — Tunnel Sealing Head
  • Enercon Industries — Flat Sealing Head
  • Enercon Industries — Don’t Be Fooled by Kilowatts
  • Enercon Industries — Get Consistent Seals: Dial In Your Induction Sealing Window
  • Enercon Industries — Super Seal, Super Seal Pro, Super Seal Max, and Super Seal Jr. Induction Cap Sealer Specifications
  • Accutek Packaging Machinery — Automatic Induction Sealer Specifications